HandHeld Oscilloscope DSO1200
- Categories:
- Diagnostic Scanner
- Brand:
- Launch X431
- Model:
- HandHeld oscilloscope DSO1200
- Comments:
- HandHeld oscilloscope DSO1200
Characteristic(Handheld Oscilloscope/Multimeter)
l Excellent Industrial Design .Direct key for Each Channel ,Time base ,Trigger and DMM,easy to operate.
l Large 5.7 inch TFT Color LCD Display ,Led backlight,Display clearly.
l USB Host/Device 2.0 full-speed interface ,support removeable disk, RS-232/LAN Optional ,Easy to control by PC or long-distance.
l High Bandwidth 200MHz+ 6000 COUNTS high precision DMM.
l High refresh rate,High Real-time Sample Rate 500MS/s, 50GS/s Equivalent-time Sample Rate.
l FFT , + , - , * , / ,X-Y, 22 kinds of auto measurements, PASS/FAIL Check ,easy to use on production line.
l Multiform Trigger mode ,2 separate Time Base in ALT Trigger mode ,easy to see 2 signal with different frequency.
l 1000 waveforms save and record.
l Battery Power Operation (Installed) Industrial Design.
l Save waveform in the following: jpg/bmp graphic file, MS excel/word file.
l Dimensions (mm):240(L)x165(W)x50(H), be carried easily.
l Labview\VB\VC Second Design instance.
5. Hardware Specification
|
MODE |
DSO1200 | ||
|
VERTICAL |
Channels |
2 | |
|
Bandwidth |
200MHz | ||
|
Rise Time |
1.7ns | ||
|
Input Impedance |
Resistance: 1M ; Capacitance: 15 pF | ||
|
Input Sensitivity |
10mV/div to 5V/div | ||
|
Input Coupling |
AC, DC and GND | ||
|
Vertical Resolution |
8 bits | ||
|
Maximum Input |
400V (DC+AC Peak) | ||
|
HORIZONTAL |
Real-Time Sampling Rate |
500MSa/s | |
|
Equivalent Sampling Rate |
50GSa/S | ||
|
Time Base Range |
5ns/div~1000s/div | ||
|
Memory Depth |
32k at Single Channel, 16k at Dual Channel | ||
|
Time Base Precision |
±50ppm | ||
|
TRIGGER |
Source |
CH1, CH2 | |
|
Mode |
Edge,Video, Pulse Width, Alternative | ||
|
X-Y MODE |
X-Axis Input |
Channel 1 | |
|
Y-Axis Input |
Channel 2 | ||
|
Phrase Shift |
Max.3 degree | ||
|
CURSORS AND MEASUREMENT |
Voltage Measuremet |
Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot | |
|
Time Measuremet |
Frequency,Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle | ||
|
Delay Measuremet |
Delay time from ch1 rising edge to ch2 rising edge | ||
|
Delay time from ch1 falling edge to ch2 falling edge | |||
|
Cursors Measuremet |
Manual, Track, Auto Measure Modes | ||
|
Waveform Signal Process |
|
CH1+/- CH2, CH1xCH2, CH1/CH2, FFT, Invert | |
|
Storage |
Storage |
15 Waveforms and Setups | |
|
METER MODE |
Maximum Resolution |
6,000 Counts | |
|
DMM Testing Modes |
Voltage, Current, Resistance, Capacitance,Diode & Continuity | ||
|
Maximum Input Voltage |
AC: 600V, DC: 800V | ||
|
Maximum Input Current |
AC: 10A, DC: 10A | ||
|
Input Impedance |
10 MΩ | ||
|
DISPLAY |
TFT LCD Type |
5.7 Inch with LED Backlight Display | |
|
Display Resolution |
240 (Vertical) x 320 (Horizontal) Dots | ||
|
INTERFACE |
USB |
USB Host / Device 2.0 Full Speed Supported | |
|
Optional |
RS232, LAN | ||
|
POWER SOURCE |
Line Voltage Range |
AC 100V ~ 240V, 50Hz ~ 60Hz; DC Input: 8.5VDC, 1500mA | |
|
Battery Power (Installed) |
6 Hours (Li-ion Battery) | ||
|
MECHANICS |
Dimension |
245 x 163 x 52 (mm) | |
|
Weight |
1.2Kgs | ||
|
Other |
GND Reference |
Oscilloscope and Multimeter Independence | |
6.Software:
Operating system: Windows NT, Windows 2000, Windows XP ,VISTA
7.SecondDesign:
Supply DEMO code (VC、VB、LABVIEW)
| Your E-mail | |
|---|---|
| To |
|
| Title | |
| Content |
English
Français
Deutsch
Español
Русский





Add to Cart
HandHeld oscilloscope DSO1200


































